Technology Combining Engineering and Insulation

The next-generation panel building system is a modern building technology where the load-bearing steel wire cage, high-density EPS insulation core and high-strength plaster/concrete layers are integrated into a single composite body. This system provides much higher thermal/sound insulation and fast site application compared to traditional reinforced concrete and prefab buildings.

1. Panel Katmanları ve Yapısal Bütünlük

1
2
3
4
5
6

TECHNICAL These are sample model and plan studies

EPS Insulation Core

Flame-retardant (Class B1), high-density EPS layer providing maximum thermal resistance.

2. Geleneksel Sistemlerle Karşılaştırma

CriterionVeloce Panel SystemTraditional Concrete / Brick
Application DurationHighly fast; fabricated parts are installed in days on site.Slow; takes months due to concrete curing times and shuttering works.
Site IntensityLow; noise and heavy construction machinery requirement is minimum.Very high; concrete mixers, shuttering and long-term workforce are required.
Insulation PerformancePerfect; thermal bridges do not occur thanks to continuous EPS core.Weak-Medium; thermal bridges form at column-beam junctions, thick sheathing is needed.
Architectural FlexibilityHigh; can be adapted to every architectural project including curved forms.Limited; column and beam axes limit the architecture.
Material ControlFull control; panels are produced in standard dimensions in factory environment.Depends on site workmanship; poured concrete quality and weather conditions affect the result.
Site Construction WasteMinimum; waste does not occur as there is no cutting to size on site.Very high; shuttering woods, mortar and brick fragments generate intense waste.
Later ModificationsCan be done in a planned way; bearing walls can be cut under engineering control.Difficult and dangerous; columns or beams cannot be touched at all.
Maintenance RequirementLow; risk of humidity, cracks or corrosion is extremely low.Medium; plaster cracks, dampness and insulation aging can be seen.

3. Teknik Özellikler ve Mühendislik Standartları

Wall and Section Parameters

Total Panel Wall ThicknessIn the range of 150 mm - 250 mm according to project and climate zone
EPS Core DensityStandard 16 - 24 kg/m³ high density insulation infill
Steel Reinforcement Wire Diameter3.0 mm galvanized, high-strength tension wires

Physical Performance Data

Heat Conductivity Coefficient (U Value)Can be reduced down to 0.18 - 0.24 W/m²K at appropriate thickness
Sound Insulation Index (Rw)45 dB - 52 dB airborne sound dampening depending on layer structure
Fire Resistance ClassEPS insulation is B1 (Flame-retardant), Class EI 90 - EI 120 with concrete plaster
WhatsApp